-40%
x-rite i1 pro 2
$ 316.8
- Description
- Size Guide
Description
x-rite i1 pro 2. Condition is Used like New.The Item is used like new,
SOLD AS IS, THE DEVICE HAS BEEN TESTED AND IS ON GOOD WORKING CONDITIONS
, No license included.
All sales are final, Returns no accepted.
PLEASE READ THE BELOW TEST RESULT BEFORE COMPLETING THE PURCHASE TO VOID MISS UNDERSTANDING'S
What is shown in the pictures is what you will receive.
i1Pro Tests
General Information
Date and Time: 8/22/2021 3:16:36 PM
Application version: 4.2.5.381, 32-bit
SDK version i1Pro: 4.2.4.5061
SDK version i1iO: 2.2.4.5061
SDK version i1Pro3: 1.0.15.5919
SDK version i1iO3: 1.0.15.5919
SDK version i1iSis: 2.0.0.4968
SDK version ColorMunki: 1.0.3.4630
SDK version i1Display2: X-Rite, Inc. SipCal Library Ver. 7.3.7 (32 bit)
Platform: Microsoft Windows 10, 64-bit
Open instrument
Connection: Successful
Open instrument: Successful
Instrument information
Instrument inspection: Successful
Serial number i1Pro: 7041766
Type: i1Pro
Revision: E
Firmware version: 634
CPLD version: 999
Dark measurement count: 125
Lamp burning time: 341.3 seconds
Spot measurement count: 54
Scan measurement count: 45
Factory calibration: 6/15/2015
Spectral Module ID: 01-d9bf1018000018
Supplier: 'EFI-ES2000'
Recertification date: -
Instrument Licenses
Measurement Modes: [Reflectance Spot, Reflectance Scan, Emission, DualReflectance Spot, DualReflectance Scan]
Licensed functionality: [Has UV LED, Has Wavelength LED, Has Zebra Ruler sensor, Max Ruler Length = 300 mm, Has Indicator LED, Spectral values, Tristimulus, Density]
Licensed Modules:
i1Match Module "Scanner": NOT licensed
i1Match Module "Monitor": licensed
i1Match Module "Printer": NOT licensed
i1Match Module "Printer RGB only": NOT licensed
i1Match Module "Printer CMYK only": NOT licensed
i1Match Module "Beamer": NOT licensed
i1Match Module "Printer Easy RGB": NOT licensed
i1Match Module "Printer Easy CMYK": NOT licensed
i1Match Module "Digicam": NOT licensed
i1Match Module "Editor": NOT licensed
i1Profiler Module "Display Profiling": NOT licensed
i1Profiler Module "RGB Printer Profiling": NOT licensed
i1Profiler Module "CMYK Printer Profiling": NOT licensed
i1Profiler Module "Printer QA": NOT licensed
i1Profiler Module "Advanced-Mode": NOT licensed
i1Profiler Module "Projector": NOT licensed
Button test
Button: Successful
Emission test
Emission calibration: Successful
Prepare the instrument for emission measurement
White measurement: Successful
Gray measurement: Successful
Black measurement: Successful
Red measurement: Successful
Green measurement: Successful
Blue measurement: Successful
Emission: Successful
Button test
Button: Successful
Noise Tests
Noise measurements: Successful
Noise result: Successful
Reflectance test
Reflectance Spot calibration: Successful
Reflectance Spot measurement 1: Successful
Reflectance Spot measurement 2: Successful
Reflectance Spot measurement 3: Successful
Reflectance Spot measurement 4: Successful
Reflectance Spot measurement 5: Successful
Reflectance Spot measurement 6: Successful
Reflectance Spot measurement 7: Successful
Reflectance Spot measurement 8: Successful
Reflectance Spot measurement 9: Successful
Reflectance Spot measurement 10: Successful
Lamp test: Successful
Reflectance drift test: Successful
Reflectance Scan calibration: Successful
Dual Reflectance Spot calibration: Successful
Dual Reflectance Spot test: Successful
Dual Reflectance Scan calibration: Successful
Positioning Sensor Test
Scan with positioning sensors: Successful (Moving distance: 26.2 cm)
*** PASS ***
**************************
i1Pro Tests
General Information
Date and Time: 2021-08-22T15:16:36
Application version: 4.2.5.381, 32-bit
SDK version i1Pro: 4.2.4.5061
SDK version i1iO: 2.2.4.5061
SDK version i1Pro3: 1.0.15.5919
SDK version i1iO3: 1.0.15.5919
SDK version i1iSis: 2.0.0.4968
SDK version ColorMunki: 1.0.3.4630
SDK version i1Display2: X-Rite, Inc. SipCal Library Ver. 7.3.7 (32 bit)
Platform: Microsoft Windows 10 (Build 19041), 64-bit
Open instrument
Connection: Successful
Open instrument '\?\usb#vid_0971&pid_2000#5&26f3984c&0&2#{989d6515-e122-4442-a357-751457f102a5}': Successful
Instrument information
Instrument inspection: Successful
Serial number i1Pro: 7041766
Type: i1Pro
Revision: E
Firmware version: 634
CPLD version: 999
Dark measurement count: 125
Lamp burning time: 341.3 seconds
Spot measurement count: 54
Scan measurement count: 45
Factory calibration: 2015-06-15
Spectral Module ID: 01-d9bf1018000018
Supplier: 'EFI-ES2000'
Recertification date: -
Instrument Licences
Measurement Modes: [ReflectanceSpot, ReflectanceScan, EmissionSpot, DualReflectanceSpot, DualReflectanceScan]
Licensed functionality: [Has UV LED, Has Wavelength LED, Has Zebra Ruler sensor, Max Ruler Length = 300 mm, Has Indicator LED, Spectral values, Tristimulus, Density]
Licensed Modules:
i1Match Module "Scanner": NOT licensed
i1Match Module "Monitor": licensed
i1Match Module "Printer": NOT licensed
i1Match Module "Printer RGB only": NOT licensed
i1Match Module "Printer CMYK only": NOT licensed
i1Match Module "Beamer": NOT licensed
i1Match Module "Printer Easy RGB": NOT licensed
i1Match Module "Printer Easy CMYK": NOT licensed
i1Match Module "Digicam": NOT licensed
i1Match Module "Editor": NOT licensed
i1Profiler Module "Display Profiling": NOT licensed
i1Profiler Module "RGB Printer Profiling": NOT licensed
i1Profiler Module "CMYK Printer Profiling": NOT licensed
i1Profiler Module "Printer QA": NOT licensed
i1Profiler Module "Advanced-Mode": NOT licensed
i1Profiler Module "Projector": NOT licensed
Button Test
Button: Successful
Emission test
Emission calibration: Successful
Prepare the instrument for emission measurement
White measurement: Successful (X=401.291 Y=422.446 Z=529.941)
Gray measurement: Successful (X=142.874 Y=149.396 Z=187.444)
Black measurement: Successful (X=0.450 Y=0.443 Z=0.864)
Red measurement: Successful (X=174.824 Y=88.230 Z=13.425)
Green measurement: Successful (X=148.930 Y=314.827 Z=56.543)
Blue measurement: Successful (X=91.272 Y=33.792 Z=476.384)
Emission: Successful
Button Test
Button: Successful
Noise Tests
Noise measurements: Successful
Noise result: Successful (electronic noise: 3.128)
Reflectance test
Reflectance Spot calibration: Successful (slope=0.0258505289 (0.150000006), WLS=0.5)
Reflectance Spot measurement 1: Successful (95.995, -0.563, 2.026)
Reflectance Spot measurement 2: Successful (95.979, -0.557, 2.048)
Reflectance Spot measurement 3: Successful (95.973, -0.544, 2.042)
Reflectance Spot measurement 4: Successful (95.964, -0.540, 2.058)
Reflectance Spot measurement 5: Successful (95.962, -0.537, 2.063)
Reflectance Spot measurement 6: Successful (95.959, -0.534, 2.068)
Reflectance Spot measurement 7: Successful (95.957, -0.535, 2.068)
Reflectance Spot measurement 8: Successful (95.957, -0.526, 2.071)
Reflectance Spot measurement 9: Successful (95.961, -0.534, 2.085)
Reflectance Spot measurement 10: Successful (95.960, -0.531, 2.078)
Lamp test: Successful (minL=95.957 meanL=95.967 MIT=0.0147240004 CIT=0.0147240004 LOT=344.99472)
Reflectance drift test: Successful (0.020)
Reflectance Scan calibration: Successful (slope=0.0258505289 (0.150000006), WLS=0.5)
Dual Reflectance Spot calibration: Successful (slope=0.0258505289 (0.150000006), WLS=0.550000012)
Dual Reflectance Spot test: Successful
Dual Reflectance Scan calibration: Successful (WLS=0.600000024)
Positioning Sensor Test
Scan with positioning sensors: Successful (min: -0.001, max: 0.261, total distance: 0.262)
*** PASS ***